Optical bonding requires precise control of UV wavelength, irradiance, curing dose, and temperature. In the manufacturing of optical lenses and prism assemblies, inconsistent curing conditions can affect bond strength, optical alignment, product quality, and production efficiency.
Traditional mercury UV lamps can present challenges such as warm-up time, output variation as the lamp ages, and unwanted heat exposure. For manufacturers working with thin optical components and UV-curable optical adhesives, these limitations can make process control more difficult.
This case study explores how a water-cooled UV LED curing conveyor was integrated into an existing optical assembly line in Baden-Württemberg, Germany, to improve curing consistency and production efficiency.
Customer: Optical lens and prism assembly manufacturer
Location: Baden-Württemberg, Germany
Application: UV adhesive bonding of lens elements and prism stacks
Equipment: CG-GHL-W400-360x27-A/C UV LED curing conveyor
Rated Power: 1500W
UV Wavelength: 365nm
UV Intensity: 18W/cm² at 100% output
Emitting Window: 360 × 27mm
Cooling System: Water cooling with a matched chiller
The objective was to replace a conventional 2kW mercury UV lamp with a more controllable UV LED curing system while retaining the existing assembly fixtures and production layout.
Before the upgrade, the customer used a mercury UV lamp to cure optical adhesive on a manual assembly bench.
Although the existing process was functional, several issues affected production:
Unstable UV output: Lamp aging could cause changes in irradiance, making curing conditions less consistent.
Long warm-up time: The mercury lamp required approximately 10–15 minutes to warm up before production.
Unwanted heat exposure: Radiant heat could affect thin lens blanks during extended operation.
Operator-dependent curing: Manually maintaining the working distance made it difficult to achieve repeatable exposure conditions.
Quality and throughput limitations: Historical production data indicated a rework and scrap rate of approximately 6%, with throughput limited to around 120 units per hour.
The engineering team needed a UV curing solution that could deliver a suitable wavelength, stable output, controlled exposure, and reliable performance during continuous production.
Following sample testing with the customer's optical adhesive, we specified the CG-GHL-W400-360x27-A/C water-cooled UV LED curing conveyor.
The system combines a high-intensity UV LED source with an adjustable-speed conveyor, allowing the curing process to be controlled through defined equipment settings rather than manual positioning alone.
The system was configured with a fixed 365nm wavelength to match the customer's adhesive requirements established during testing.
Selecting the appropriate UV wavelength is essential because the photoinitiator in a UV-curable adhesive must absorb sufficient energy at the emitted wavelength to initiate polymerization.
Before selecting a UV curing system, manufacturers should verify the adhesive's spectral response, recommended irradiance, and required curing dose.
The system provides a specified UV intensity of 18W/cm² at 100% output, with adjustable output from 0–100%.
High irradiance can help deliver the required curing dose within a shorter exposure period when the adhesive, bond geometry, and optical path are suitable.
The actual curing result depends on irradiance at the workpiece, exposure time, adhesive formulation, and the accessibility of UV light to the bonding interface.
The integrated water-cooling system and matched chiller help manage heat generated by the UV LED assembly during operation.
This configuration supports stable equipment operation and helps reduce thermal effects associated with prolonged exposure to conventional UV sources.
For temperature-sensitive optical components, the workpiece temperature should still be verified under actual production conditions.
The integrated conveyor allows the customer to adjust exposure time through belt speed.
Once the required curing dose has been established through testing, the production team can define a suitable operating recipe and reduce variation caused by manual handling.
The adjustable output also allows the system to be evaluated at different intensity settings during process development.
| Parameter | Specification |
|---|---|
| Model | CG-GHL-W400-360x27-A/C |
| Rated Power | 1500W |
| UV Intensity | 18W/cm² at 100% output |
| Output Adjustment | 0–100% |
| Standard Wavelength | 365nm, fixed per unit |
| Optional Wavelengths | 385nm, 395nm, 405nm |
| Emitting Window | 360 × 27mm |
| Cooling Method | Water cooling with matched chiller |
| Conveyor | Integrated adjustable-speed belt conveyor |
| Working Distance | 30–50mm |
Note: Confirm the applicable wavelength configuration, irradiance measurement conditions, and equipment specifications before ordering. UV intensity and curing performance should be evaluated at the actual working distance and production setup.
The UV LED curing conveyor was supplied as a complete system, including the UV head, driver, chiller, and conveyor frame.
It was retrofitted into the customer's existing assembly cell without requiring changes to the original fixture layout.
Commissioning included three key activities.
The equipment was installed, the cooling system was connected, and the operating conditions were checked before production trials.
A radiometer was used to evaluate UV irradiance distribution across the emitting area. The conveyor speed and output settings were then adjusted based on the curing dose validated during adhesive testing.
An eight-hour production run was conducted to evaluate operating stability. Tack, peel performance, and curing consistency were checked at regular intervals.
This validation process helped establish operating parameters for production and low-dose trials.
According to the project data, the production line showed improvements after the equipment upgrade.
| Performance Metric | Before: Mercury Lamp | After: UV LED Conveyor |
|---|---|---|
| Reported Curing Cycle | 90 seconds | 20 seconds |
| Reported Throughput | 120 units/hour | 215 units/hour |
| Rework and Scrap Rate | 6.0% | 1.2% |
| Warm-up Time | 10–15 minutes | No lamp warm-up required |
| UV Source Rated Power | 2kW | 1500W |
| Observed Lens Distortion | Observed during extended runs | Not observed during the reported evaluation |